Home/Abutments/BIONIKA ECOPLANT, Impression coping for closed tray, angled, type-A
BIONIKA ECOPLANT, Impression coping for closed tray, angled, type-A

Compatible: BIONIKA ECOplant

BIONIKA ECOPLANT, Impression coping for closed tray, angled, type-A

SKU 504.366.351.215UDI-DI 5993220143235Ø 3.5 mm (gray) · L 12 mm · 15°
RON 310.00
Unit price, incl. VAT

Compatible system

Quantity discount

calculated per size
102050

Add 10 pcs more for −15%: RON 263.50 per pcs

Savings: RON 310.00
Minimum order: 10 pcsThis size is not in stock, so the minimum order is 10 pcs.
● Available to order (min. 10 pcs)

Description

Brand characteristics

The BIONIKA ECOplant implant system combines a Cone, Hex, and Cylinder connection geometry, providing a proven, precise, and micromovement-free fit widely recognised in engineering practice.

The 30° conical angle ensures optimal force transmission while directing loads deep into the implant body, thereby reducing stress on the cortical bone.

Placement at or slightly below the cortical level supports long-term bone preservation, while the platform-switching design enables natural soft-tissue closure, creating a biological seal around the implant shoulder.

The spirally micro-grooved, self-locking thread structure and cycloid thread profile effectively dissipate dynamic forces, maintaining micromovement-free stability and promoting rapid osseointegration.

With its anatomical root-shaped design, deep thread profile, and bone-condensing geometry, the ECOplant implant ensures excellent primary stability and allows for immediate loading when clinically indicated.

The rounded apex facilitates precise surgical placement and minimises bone stress during insertion.

Geometry characteristics

Impression Coping with Angle Correction and Fixed Orientation for Precise Transfer

The Impression coping for closed tray, angled, type-A is an implant-level component designed for closed tray impression techniques. Its angled geometry allows for angle correction, making it possible to accurately capture the position of implants placed at non-ideal angles. The Type A orientation ensures that the coping consistently locks into the same predefined rotational position on the implant, supporting precise prosthetic alignment.

The Type A system refers to a design where one flat surface of the connecting interface always aligns identically relative to the top part of the coping. This facilitates predictable and reproducible adjustments, particularly important in multiple-implant restorations.

Main Advantages:

  • Angled design: Enables angle correction for non-ideal implant positions.
  • For closed tray technique: Impression taking without removing the coping from the patient’s mouth.
  • Type A positioning: Flat surface of the connector consistently aligned with the top part.
  • Implant-level connection: Direct fit to the implant interface.
  • Biocompatible metal: Precisely machined, durable, and sterilisable material.

Indications:

The Impression coping for closed tray, angled, type-A is the ideal solution in clinical cases requiring both angle correction and fixed positioning during impression taking, especially in multi-implant configurations.

The product image is for illustration purposes only; colour and geometry may vary depending on selected parameters.