Home/Abutments/BIONIKA BIOLEVEL, Impression coping for closed tray, angled, type-A
BIONIKA BIOLEVEL, Impression coping for closed tray, angled, type-A

Compatible: 9 systems

BIONIKA BIOLEVEL, Impression coping for closed tray, angled, type-A

SKU 500.366.271.215UDI-DI 5993221407091Ø 2.75 mm (gray) · L 12 mm, 15°
RON 310.00
Unit price, incl. VAT

Compatible system — which one do you need?

Diameter × Length and angle

DiameterØ 2.75 mm (gray)Length and angleL 12 mm, 15°
L 12 mm, 15°L 12 mm, 25°L 12 mm, 35°
Ø 2.75 mm (gray)
Ø 3 mm (yellow)
Ø 3.5 mm (purple)
Ø 4.5 mm (blue)
Ø 5.7 mm (green)

Quantity discount

calculated per size
102050

Add 10 pcs more for −15%: RON 263.50 per pcs

Savings: RON 310.00
Minimum order: 10 pcsThis size is not in stock, so the minimum order is 10 pcs.
● Available to order (min. 10 pcs)

Description

Brand characteristics

The BIONIKA Biolevel implant system is based on a 90° Cone & Hex connection that ensures a stable, micromovement-free fit and precise force transmission.

When the implant shoulder is placed at or slightly below the cortical level, it promotes bone preservation, while the internal platform-switching design allows the bone to naturally grow over the implant edge.

The spirally micro-grooved, self-locking thread structure optimizes load distribution and facilitates rapid osseointegration. Meanwhile, the anatomical root-shaped body and rounded apex assist in positioning and enhance primary stability.

The Biolevel system is compatible with numerous international implant platforms, including:

  • ADIN® Standard®
  • Alpha Bio® IH 90°
  • CORTEX® Internal Hex Platform
  • Dentis®
  • MIS® Seven®
  • SGS®
  • Tri-Vent®
  • Zimmer® (Tapered Screw Vent®)

This broad compatibility enables BIONIKA Biolevel implants to integrate seamlessly into various clinical systems, while maintaining the hallmark Hungarian precision and long-term reliability.

Geometry characteristics

Impression Coping with Angle Correction and Fixed Orientation for Precise Transfer

The Impression coping for closed tray, angled, type-A is an implant-level component designed for closed tray impression techniques. Its angled geometry allows for angle correction, making it possible to accurately capture the position of implants placed at non-ideal angles. The Type A orientation ensures that the coping consistently locks into the same predefined rotational position on the implant, supporting precise prosthetic alignment.

The Type A system refers to a design where one flat surface of the connecting interface always aligns identically relative to the top part of the coping. This facilitates predictable and reproducible adjustments, particularly important in multiple-implant restorations.

Main Advantages:

  • Angled design: Enables angle correction for non-ideal implant positions.
  • For closed tray technique: Impression taking without removing the coping from the patient’s mouth.
  • Type A positioning: Flat surface of the connector consistently aligned with the top part.
  • Implant-level connection: Direct fit to the implant interface.
  • Biocompatible metal: Precisely machined, durable, and sterilisable material.

Indications:

The Impression coping for closed tray, angled, type-A is the ideal solution in clinical cases requiring both angle correction and fixed positioning during impression taking, especially in multi-implant configurations.

The product image is for illustration purposes only; colour and geometry may vary depending on selected parameters.